Form Factors

Enterprise SSD Form Factors

A reference of common enterprise/datacenter SSD form factors. Physical and electrical parameters (dimensions, power, PCIe speed, connector) come from published EDSFF/SNIA/NVMe specs and are reasonably solid. Board-level parameters (NAND package count, DRAM count, hold-up capacitor count) are not part of any form-factor spec — they're a per-vendor, per-model PCB design choice constrained by the available footprint, so these are left blank below to be filled in per drive.


U.2 (SFF-8639, "2.5-inch")

Parameter Value
Dimensions 69.85 mm x 100.45 mm (2.5" footprint); thickness 7 mm, 9.5 mm, or 15 mm
Cooling method Passive — chassis airflow across the metal case; no integrated heatsink
Max power ~9-25 W typical (SFF-8639 defines multiple power classes; higher-power drives generally need the 15 mm case for surface area)
Max PCIe speed Up to PCIe Gen5 x4 (connector/spec headroom exists to Gen5+; most shipping drives are Gen4 x4)
# of NAND placements
# of DRAM
# of hold-up caps
Connector SFF-8639 (mechanically similar to SATA Express, repurposed pins for PCIe)
Protocols supported NVMe (PCIe), SAS, SATA — single-protocol per drive
Power rails 3.3 V, 5 V, 12 V
Hot-plug Yes
Notes Legacy-dominant enterprise/datacenter form factor; being displaced by U.3 and EDSFF (E3.S) in new designs

U.3 (SFF-TA-1001)

Parameter Value
Dimensions Same as U.2: 69.85 mm x 100.45 mm, 7/9.5/15 mm thickness
Cooling method Passive — chassis airflow
Max power Similar envelope to U.2 (~9-25 W typical)
Max PCIe speed Up to PCIe Gen5 x4
# of NAND placements
# of DRAM
# of hold-up caps
Connector Modified SFF-8639 with tri-mode pinout
Protocols supported Tri-mode: NVMe, SAS (up to 24G), or SATA — auto-negotiated in the same physical bay/backplane slot
Power rails 3.3 V, 5 V, 12 V
Hot-plug Yes
Notes Mechanically compatible with U.2 bays; lets a backplane support NVMe/SAS/SATA drives interchangeably without redesign

E1.S (EDSFF 1U Short, "gum stick")

Parameter Value
Dimensions ~118.75 mm length; width fixed to fit vertically in a 1U chassis; thickness variants: 5.9 mm, 8.0 mm, 9.5 mm, 15 mm, 25 mm
Cooling method 5.9 mm/9.5 mm: passive/minimal, chassis airflow; 15 mm/25 mm: integrated heat spreader or heatsink
Max power ~20 W (9.5 mm) up to ~25 W (15 mm, 25 mm) — varies by vendor
Max PCIe speed Up to PCIe Gen5, x4 standard, x8 optional on some variants
# of NAND placements
# of DRAM
# of hold-up caps
Connector EDSFF native connector (SFF-TA-1006)
Capacity range (typical) ~800 GB - 8 TB
Hot-plug Yes
Notes Designed as the boot-drive/mainstream successor to M.2 in hyperscale 1U servers; up to 32 drives per 1U chassis in dense configs

E1.L (EDSFF 1U Long, "ruler")

Parameter Value
Dimensions ~318.75 mm length; thickness variants: 9.5 mm, 18 mm
Cooling method 9.5 mm: passive; 18 mm: heat spreader/heatsink for higher sustained power
Max power ~25 W (9.5 mm), ~40 W (18 mm)
Max PCIe speed Up to PCIe Gen5, x4/x8
# of NAND placements
# of DRAM
# of hold-up caps
Connector EDSFF native connector (SFF-TA-1006)
Capacity range (typical) Up to ~60 TB per drive; ~1 PB per 1U chassis achievable
Hot-plug Yes
Notes Maximizes capacity density per rack unit; primarily targeted at QLC-based, capacity-optimized (cold/warm tier) storage

E2 (EDSFF 2U, emerging / not yet finalized)

Parameter Value
Dimensions ~200 mm (length) x 76 mm (height) x 9.5 mm (thickness) — sized to fit vertically in a 2U chassis
Cooling method Passive air cooling may not be sufficient at the top of its power range — proposal explicitly flags that liquid or other alternative cooling may be required
Max power Up to ~80 W (typical operation cited around 20-30 W)
Max PCIe speed PCIe Gen6 x4 (or better) targeted
# of NAND placements 64 NAND package sites — this is one of the few form factors above where the spec itself targets a specific NAND package count, driven by the capacity goal below
# of DRAM
# of hold-up caps
Connector Builds on SFF-TA-1002 and SFF-TA-1009 (same connector family as E3)
Capacity range (typical) Up to ~1 PB per drive (QLC-based); up to ~40 drives (~40 PB) in a 2U node
Hot-plug Yes (expected, consistent with other EDSFF form factors)
Status Proposed, not yet a ratified/mature spec. SNIA SFF TA TWG opened this as a new project (with OCP/Micron involvement) in March 2025; first draft targeted 1-2 months after that. Treat all values here as directional/early — they're likely to shift before finalization.
Notes Positioned as a "warm tier" form factor — denser and cheaper per TB than E1.L, sitting between high-capacity SSDs and HDDs for AI/HPC/HCI datasets that need better-than-HDD access speed without full flash-tier cost

E3.S (EDSFF 3" Short)

Parameter Value
Dimensions 76 mm (height) x 112.75 mm (length); thickness: 7.5 mm (1T) or 16.8 mm (2T)
Cooling method 1T: passive, chassis airflow; 2T: heat spreader/heatsink for higher power
Max power 1T: ~25 W; 2T: ~40 W
Max PCIe speed 1T: PCIe Gen5 x4; 2T: PCIe Gen5/Gen6, x4/x8/x16
# of NAND placements
# of DRAM
# of hold-up caps
Connector SFF-TA-1002 "Protocol Agnostic Multi-Lane High Speed Connector"
Capacity range (typical) Roadmapped toward 60+ TB
Hot-plug Yes
Notes Considered the intended long-term replacement for U.2/U.3 2.5" drives; better signal integrity than SFF-8639 at high PCIe speeds

E3.L (EDSFF 3" Long)

Parameter Value
Dimensions 76 mm (height) x 142.2 mm (length); thickness: 7.5 mm (1T) or 16.8 mm (2T)
Cooling method 1T: passive/heat spreader; 2T: heatsink, larger surface area for sustained higher power
Max power 1T: ~40 W; 2T: ~70 W
Max PCIe speed PCIe Gen5 (Gen6 roadmapped), x4/x8/x16
# of NAND placements
# of DRAM
# of hold-up caps
Connector SFF-TA-1002
Capacity range (typical) Highest-capacity EDSFF option; targets both storage-dense and performance-dense (accelerator-capable) chassis
Hot-plug Yes
Notes Larger board area also positions E3.L as a candidate for GPU/accelerator/NIC modules, not just SSDs, in future E3-based chassis

M.2 (2280 / 22110)

Parameter Value
Dimensions 22 mm width; common lengths 30/42/60/80/110 mm (enterprise drives typically use 22110 — 110 mm — for extra board space)
Cooling method Passive; typically none integrated, relies on motherboard/chassis heatsink or airflow — a common bottleneck at sustained enterprise loads
Max power ~4-11 W typical (thermally constrained by the small, unshielded PCB)
Max PCIe speed PCIe Gen4 x4 common; Gen5 x4 emerging
# of NAND placements
# of DRAM
# of hold-up caps
Connector Edge connector, keyed (B, M, or B+M key)
Hot-plug No (typically socketed, not hot-swappable)
Notes Used in enterprise mainly for boot drives, cache/tiering drives, or edge/embedded servers — not primary bulk data storage, due to thermal and capacity limits vs. EDSFF/U.2

PCIe Add-in Card (AIC / CEM form factor)

Parameter Value
Dimensions Standard height 111.15 mm or low-profile 68.9 mm bracket; length up to ~312 mm (full-length), ~168 mm (half-length) common; single/dual/triple slot width
Cooling method Passive heatsink or active fan, sized to the card's power envelope; full-height cards allow the largest heatsinks of any form factor here
Max power Up to 300 W air-cooled (spec allows up to 600 W with adequate cooling), though SSD AICs are typically far lower (25-75 W)
Max PCIe speed Up to PCIe Gen5/Gen6, x1 to x16 (standard slot electrical/mechanical range)
# of NAND placements
# of DRAM
# of hold-up caps
Connector Standard PCIe edge (card) connector
Hot-plug Generally no (some enterprise implementations support surprise/managed hot-plug)
Notes Largest board area of any form factor here — used for very high-capacity or high-performance drives, or drives with on-board compute/FPGA/computational storage functions

Notes on Blank Fields

NAND package count, DRAM package count, and hold-up capacitor count are not standardized by any of the form-factor specs above — they're determined per-drive by the vendor based on target capacity, DRAM-to-NAND ratio, and required power-loss-protection energy budget, all within the available PCB area for that form factor/thickness. These are best filled in from a specific drive's datasheet or teardown rather than the form-factor spec itself. As a rough intuition: thicker/longer form factors (E1.L, E3.L 2T, U.2 15mm, PCIe AIC) have more board area and generally allow more NAND packages and more hold-up capacitance than thin/short ones (M.2, E1.S 5.9mm).

Sources